上海榮計達儀器科技有限公司
參 考 價 | 面議 |
產品型號JTX-II
品 牌
廠商性質其他
所 在 地上海市
紡織服裝機械網采購部電話:0571-88918531QQ:2568841715
聯(lián)系方式:查看聯(lián)系方式
更新時間:2024-02-10 15:47:16瀏覽次數:85次
聯(lián)系我時,請告知來自 紡織服裝機械網該儀器是用來測定涂料涂層(表面狀的)耐洗刷性能的儀器。有時還用來評價任何薄膜復合處理過的表面如:油漆、電鍍、地板、罩面層、木材密度等形式表面的性能。該裝置對涂刷于標準試板上的涂料行進洗刷。儀 器采用可編程控制,液晶屏顯示,操作簡單,具有信息斷電保護功能。性能可靠,使用靈活方便。
一、產品簡介:
該儀器是用來測定涂料涂層(表面狀的)耐洗刷性能的儀器。有時還用來評價任何薄膜復合處理過的表面如:油漆、電鍍、地板、罩面層、木材密度等形式表面的性能。該裝置對涂刷于標準試板上的涂料行進洗刷。儀 器采用可編程控制,液晶屏顯示,操作簡單,具有信息斷電保護功能。性能可靠,使用靈活方便。
Product introduction:
This instrument is used to determine the scrub resistance of paint coatings (surface-like). It is also sometimes used to evaluate the performance of any film composite treated surface such as: paint, electroplating, flooring, overlay, wood density and other forms of surface. The device scrubs the paint applied on the standard test plate. The instrument adopts programmable control, LCD screen display, simple operation, and information power protection function. Reliable performance, flexible and convenient to use.
二、技術參數:
?刷子規(guī)格: 38X90mm的底板上均布60個Ф3孔穿zhu毛?毛長19mm
?刷子自重(包括刷具): 450±2g
?滴液速度:每秒鐘滴加大約0.04g
?刷子行程: 300mm
?刷子運行頻率: 37±1次/分
?計數控制顯示位數:5位
?計數范圍:99999次
?試板尺寸:430X150X3mm
?電機功率:25W
?電源:220V 50HZ
?外型尺寸:570X420X300mm
?整機重量:32kg
Technical parameters:
Brush specifications: 60 Ф3 holes are worn on the 38X90mm floor, and the hair length is 19mm.
? Brush weight (including brush): 450 ± 2g
Dropping speed: about 0.04g per second
Brush stroke: 300mm
Brush running frequency: 37 ± 1 times / minute
? Counting control display digits: 5 digits
? Counting range: 99999 times
? Test plate size: 430X150X3mm
? Motor power: 25W
? Power supply: 220V 50HZ
? Overall dimensions: 570X420X300mm
? Whole machine weight: 32kg
三、使用方法:
?預先將毛刷放在20°C的水中浸泡30分鐘,浸泡深度為12mm,然后取出毛刷用力壓干,再在0.5%的皂液中浸泡10分鐘。
?將試板放在工作盤內,將兩發(fā)固定栓卡在試板邊框上,擰緊螺母,使試件在工作過程中沒有移動現(xiàn)象。
?將刷子與刷具放在一起。放入平行滑架內即可。
?將0.5%濃度的皂液放滿儲蓄槽,再把出水管插入水泵的出水口,打開總電源開關,打開泵電源開關(泵電源應聯(lián)機在機身的插座上),出水管向試板輸送皂液。送液量的大小可通過調節(jié)泵流量調節(jié)桿來控制。
?按“設定"鍵(詳見鍵盤操作說明),設定所需洗刷次數。一切工作**緒,按運行按鈕,刷子開始運行,控制器進行加法計數。
?觀察試板中間10厘米處有無磨損現(xiàn)象及露底現(xiàn)象,中途欲停機,則按下“暫停"鍵,停止洗刷。
?當試件未露底,實際計數值已達到設定值而停機時,如果繼續(xù)實驗,通過鍵盤操作,將實際計數值清零,再按運行按鈕,計數器重新開始計數,累計實驗結實。
?如果用于檢驗產品,將設定值為為合格的洗刷次數,按運行“按鈕",當實際值等于設定值后自動停機,檢查試板是否露底,以此判斷產品是否合格。
Third, use method:
? Soak the brush in water at 20 ° C for 30 minutes in advance, soak the depth of 12mm, then take out the brush and press it dry, and soak it in 0.5% soap solution for 10 minutes.
? Place the test plate in the work plate, clamp the two bolts on the frame of the test plate, and tighten the nut so that the test piece does not move during the work.
? Put the brush and brush together. Just put it in the parallel carriage.
Fill the storage tank with 0.5% strength soap solution, then insert the outlet pipe into the water outlet of the pump, turn on the main power switch, turn on the pump power switch (the pump power should be connected to the socket of the body), and the outlet pipe goes to the test board. Transport soap. The amount of liquid delivered can be controlled by adjusting the pump flow adjustment lever.
? Press the “Set" key (see the keyboard operation instructions for details) to set the required number of scrubs. Everything works, press the run button, the brush starts running, and the controller counts up.
? Observe whether there is abrasion and exposed bottom at 10 cm in the middle of the test plate. If you want to stop the machine midway, press the "pause" button to stop scrubbing.
? When the test piece is not exposed and the actual count value has reached the set value and the machine stops, if you continue the experiment, clear the actual count value by keyboard operation, and then press the run button, the counter restarts counting and the cumulative experiment is solid.
? If it is used for product inspection, set the set value as the number of qualified scrubbing times and press the “button" to run. When the actual value is equal to the set value, it will automatically stop and check whether the test plate is exposed to determine whether the product is qualified.
四、產品特點:
?該機采用了**的平行滑架,使刷子在工作過程中始終保持平行運行,重量恒定??朔藝鴥葯C型的卡刷,刷掉和搖擺現(xiàn)象。
?采用新型線性往復機構,改進了國內機型的非線性往復運動,使300mm行程中刷洗均勻。
?采用水泵自動循環(huán)送皂液系統(tǒng),減輕了以往在運行過程中人工不斷加皂液的工作,實現(xiàn)了自動化控制。本儀器采用64X128點陣液晶屏顯示,顯示清晰,操作方便,能顯示傳感器動態(tài)信息,具有數據儲存斷電記憶功能。
Fourth, product characteristics:
? The machine uses a ** parallel carriage to keep the brush running in parallel during the work, and the weight is constant. It overcomes the card swipe, swipe and swing phenomenon of domestic models.
? The new linear reciprocating mechanism is adopted to improve the non-linear reciprocating motion of domestic models and make the brushing uniform during the 300mm stroke.
? Adopting automatic circulating soap liquid delivery system by water pump, which reduces the work of manually adding soap liquid in the past during operation, and realizes automatic control. This instrument adopts 64X128 dot matrix LCD display, which is clear and easy to operate. It can display the dynamic information of the sensor and has the function of data storage and power failure memory.
五、注意事項:
?使用前請將刷放在20℃的水浸泡30min,然后用力壓干再在0.5%肥皂液中浸泡10min。
?為保證試驗數據的準確性和重現(xiàn)性請選擇均勻一致的底材按同樣的涂裝工藝制備樣品。
?結果判定以試板中間長度100mm區(qū)域涂層破壞情況為依據。
?當刷毛磨損至長度小于16mm時必須重新更換刷子。
Five, matters needing attention:
? Before use, please soak the brush in water at 20 ℃ for 30min, then dry it by pressing it hard and then soak it in 0.5% soap solution for 10min.
?In order to ensure the accuracy and reproducibility of the test data, please choose a uniform substrate and prepare samples with the same coating process.
?The results are judged based on the damage of the coating in the area of 100mm in the middle of the test plate.
?When the bristles wear to less than 16mm, the brush must be replaced again.